أسئلة ؟دعونا نتحدث
هل تحتاج إلى مساعدة؟
هل تحتاج إلى مساعدة؟الدردشة معنا على Whatsapp

مرحبا بكم في Huajie أتمتة

الهاتف

+8617538627299

فئات المنتجات موقعك: Home>>فئات المنتجات>> الجسم الرئيسي
السابقالتالي

السلامة شعاع الاستشعار

    الخط الساخن لاستشارات الخدمات العالمية: +8617538627299
  • تفاصيل المنتج

  • اتصل بنا


السلامة شعاع الاستشعار

Product Classification

  •  Single sensor head

single sensor head.jpg
















  • Double senso head

double senso head.jpg

Operation instructions

  • Overall Characteristics

  1. Adopt the color corresponding plug-in socket, simple wiring, convenient and accurate.

  2. Adopt microcomputer control technology, high system integration and strong stabiity.

  3. The international universal optical lens design, good focusing and reasonable controlled angle, easy to instal.

  4. Adopt German receiving filter, decoding and amplification system to effectively solve the problem of anti-natural sunlight interference.

  5. Transmiting head adopt low consumption high pulse transmiting technology, far transmiting distance, long service life.

  6. It has a design for connecting and outputing singie or double groups of transmiting and receiving lenses respectively, and the connection is good inshielding. lt can control single light beam, or control dual light beams.

  7. When the light is blocked, the output can be flexible choice of normally open or normally closed contact signal.

  8. Wide voltage input design, AC/DC 12-30V power input.

  9. With receiving head short connection fault alarm function.

  • Overview

Overview.png

  • الاحتياطات


  1.  1.Single Beam must be connected into Group A (White Socket,. Double beam must be connected into Group AB (Both White and Black Socket

  2. When fixing the electric eyes, the installation holes should be o13mm.Installation height of single light beams is 60cm from the ground.

  3. Instealation height of double ight beams, one sets beams should be 30cm from theground, the second sets beams should be 9Ocm from the ground.

  4. The receiving and transmiting electric eyes, have a certain detecion range, but it must be aligned duing installation to ensure the consistency of thehorizontal and vertical directions.

  5. Between the receiving and transmiting electric eves, keep away from the bonsai or other obiects to avoid error action.

  6. This system has high anti-interference ability, but should avoid direct sunlight to the electric eye when installing.

  7. Please make sure the installation height should be at least 20 cm from the ground

  • Technical parameters

  1. Power supply: AC/DC 12-30V

  2. Static current: 18mA

  3. Action current: 58mA

  4. Max matched distance: 10 meters

  5. Output connect: NO/NC selection by dial switch

  6. Transmitting cable length: 5.5 meters (blue)

  7. Receiving cable length: 5.5 meters (black)

  8. Beam light: Single beam / double beam light

  9. Working temperature: -42°C~45°C

  10. Working humidity: 10-90%RH

  11. Dimension (main controller):105.5(L)x53.4(W)x28.5(H)mm

  12. Dimension (Electric eye):15.5(ø)x18(H)mm, Hole: 13(ø)x19(D)mm